Tim J.M. Jaspers, Francisco Caetano, Cris H.B. Claessens, Carolus H.J. Kusters, Rixta A.H. van Eijck van Heslinga, Floor Slooter, Jacques J. Bergman, Peter H.N. De With, Martijn R. Jong, Albert J. de Groof, Fons van der Sommen
9 min
Imagine scanning thousands of endoscopic images during routine surveillance for Barrett's esophagus, where early cancerous lesions (neoplasia) appear in less than 1% of cases. This is a low-prevalence setting: rare targets amid vast normal data, mimicking the 'low-prevalence effect' where even experts miss subtle anomalies due to skewed expectations. CADe (Computer-Aided Detection) systems promise to act as a tireless second reader, flagging suspects to reduce misses. But most CADe models train on balanced datasets, overestimating performance when deployed in real-world rarity—leading to prevalence shift, where test distributions mismatch training, causing excessive false positives, alarm fatigue, and overlooked cancers.
The RARE25 challenge, hosted at MICCAI/EndoVis, bridges this gap with the largest public Barrett's esophagus dataset: 3,000+ labeled training images (highly imbalanced) and a hidden 25,000-image test set sampled to true clinical prevalence (~1% positives). Eleven teams from 7 countries competed using diverse deep learning architectures, pretraining, ensembling, and calibration. Evaluation used prevalence-aware metrics prioritizing high sensitivity (catching rares) at operating points that balance clinical trade-offs like false positive rates—avoiding misleading aggregates like AUROC that ignore deployment reality.
Top methods showed strong discriminative power but low positive predictive value (PPV)—many flagged regions weren't neoplasia, highlighting the intrinsic difficulty. All submissions relied on fully supervised classification despite 99%+ normal training data, ignoring prevalence-agnostic alternatives like anomaly detection (learning 'normal' distributions to flag outliers) or one-class learning. This underexplored direction aligns better with surveillance: model normality from abundant clean data, sensitize to rare pathologies without needing scarce positives. RARE25 exposes how ignoring prevalence risks overoptimism, urging benchmarks that simulate workflows.
Barrett's neoplasia detection classifies images as non-dysplastic (NDBE) or neoplastic (NEO), critical for timely intervention in esophageal cancer precursors. RARE25 catalyzes robust CADe by releasing data/tools for reproducible progress. Lessons generalize to other rare-event domains (e.g., early cancers, anomalies): prioritize realistic evaluation, explore unsupervised methods, and design for human-AI teams. By quantifying gaps—e.g., supervised limits in imbalance— it pushes toward deployment-ready systems reducing diagnostic errors in high-stakes surveillance.
Computer-aided detection (CADe) of early neoplasia in Barrett's esophagus is a low-prevalence surveillance problem in which clinically relevant findings are rare. Although many CADe systems report strong performance on balanced or enriched datasets, their behavior under realistic prevalence remains insufficiently characterized. The RARE25 challenge addresses this gap by introducing a large-scale, prevalence-aware benchmark for neoplasia detection. It includes a public training set and a hidden test set reflecting real-world incidence. Methods were evaluated using operating-point-specific metrics emphasizing high sensitivity and accounting for prevalence. Eleven teams from seven countries submitted approaches using diverse architectures, pretraining, ensembling, and calibration strategies. While several methods achieved strong discriminative performance, positive predictive values remained low, highlighting the difficulty of low-prevalence detection and the risk of overestimating clinical utility when prevalence is ignored. All methods relied on fully supervised classification despite the dominance of normal findings, indicating a lack of prevalence-agnostic approaches such as anomaly detection or one-class learning. By releasing a public dataset and a reproducible evaluation framework, RARE25 aims to support the development of CADe systems robust to prevalence shift and suitable for clinical surveillance workflows.
Alex: So it's forcing the AI to be picky—high catch rate but mostly right flags, or it drowns the doctor in junk alerts?
Sam: Precisely. The paper shows top systems looked strong on those older scores but scored under 4 percent here—meaning for every true hit at that catch level, over 25 flags were false. This reveals why supervised methods, which learn to classify balanced training examples, struggle: the public training set has just over 3,000 images, with neoplasia in only about 5 percent. One approach that might fit better is medical anomaly detection, where the system learns what all the normal esophagus looks like deeply, then flags anything that doesn't match—like a smoke detector trained only on clean air but sensitive to the slightest whiff of smoke.
Alex: Huh, so the benchmark's private test set with over 25,000 images, sampled super rare, exposes that gap between lab training and clinic use?
Sam: Yes—and it's the largest public Barrett's set yet for training, all from routine scans on the same equipment. By limiting teams to one submission a day and supervised methods only, it stresses real progress without tricks.
Alex: So all these supervised methods—ones trained directly to label images as normal or abnormal—topped out under 4 percent on that picky score. But how did they make the score so reliable, given how few bad cases there are?
Sam: They repeat the test thousands of times to smooth out luck from the tiny number of rare images. Each time, they keep every normal image but randomly pick a fresh handful of the cancerous ones to match real-world odds—one bad per hundred normals—then average the results. Researchers call this bootstrapping, like drawing samples with replacement from a small bag of marbles to guess the true mix without needing millions more marbles.
Alex: Right—like testing a rare defect detector by simulating many shifts, not just one run. And the teams? What tricks did they try with the limited training images?
Sam: Eleven teams from seven countries entered, all sticking to supervised learning on the public set of about 3,000 images. Most built ensembles—groups of several models voting together—like having a committee check each image to reduce mistakes from any one viewer. They often started with pre-trained networks, systems first taught on millions of everyday photos or stomach scans, then fine-tuned here.
Alex: Okay, so ensembles and pre-training help generalize from scarce data. But even then, at 90 percent catch rate, mostly false flags—does the bootstrapping show that's consistent across repeats?
Sam: Yes, the median PPV stayed below 4 percent for leaders, with tight confidence bands from 1,000 bootstraps confirming it's no fluke. This setup stresses real deployment: AUROC looked solid for overall separation, AUPRC decent for ranking rares, but PPV@90 percent recall exposed the false-positive load—like 25 wrongs per true hit in a hundred-patient scan. No team cracked rarity without shifts, suggesting anomaly detection merits more tests despite the supervised-only rules.
Alex: Huh. So the benchmark's resampling forces facing the clinic's alarm fatigue head-on, and current tweaks aren't enough yet.
Alex: What stood out among the top entries—like how did the leader pull slightly ahead?
Sam: The top team, IMSY, built a massive group of 40 models working together, each spotting slightly different patterns to cut down errors—like a team of spotters at a crowded event where one might miss what another catches. They mixed networks pre-trained on everyday photos and gut scans, then fine-tuned with tricks to ignore differences between clinics, such as flipping gradients during training so the system learns shared disease signs over site quirks. This ensemble hit the highest score on the key metric, about 52 percent better than the fifth-place team.
Alex: Okay, so clinic-ignoring tweaks in a huge ensemble give that edge. Did anyone simplify with just loss tweaks?
Sam: Yes, one team used a special penalty setup that ignores obvious normal images and hammers hard-to-classify ones, like a coach drilling only the toughest plays instead of easy wins. Called Asymmetric Loss, it ran on a single network pre-trained on millions of photos, with heavy image shuffling like random crops to mimic variety. Rankings held steady—the leader topped 60 percent of the simulated clinic runs on the main score.
Alex: Huh, so penalties and duplicates target imbalance without big teams of models. How consistent were the rankings across those repeated tests?
Sam: Differences shone brightest when demanding near-perfect catches, where false alarms separated the pack, not overall ranking ability. Visually, all struggled with faint early signs, like subtle texture shifts, but leaders grabbed some where others blanked, pointing to better weak-signal use.
Alex: Right, incremental steps like clinic-proof ensembles or smart penalties yield gains, but subtle cases expose the gap. Makes the under-4-percent reality feel earned, not a fluke.
Sam: Precisely. The variety—from giant ensembles to tuned singles—shows no magic bullet yet, just meaningful progress in facing rarity head-on.
Alex: So pulling it all together, these tweaks show some progress, but the core challenge persists—no team broke past that low bar on the key score. What's the upshot for doctors in the clinic?
Sam: In practice, low scores mean heavy false alarms—potentially hundreds per real case—building fatigue, slowing scans, and eroding trust in the tool. Modest gains are there, like the leader edging 52 percent ahead of mid-pack on repeats, but deployment needs balancing sensitivity against that burden to aid, not hinder, workflows.
Alex: Makes sense—trust matters as much as accuracy. Any caveats in the setup itself?
Sam: A few. Data came from one device type across 12 centers, so site-specific lighting or protocols might limit broader use. Scarce training positives made internal splits unstable, risking over-optimism. Training images had anonymization marks missing in tests, adding subtle mismatches. No anomaly detection entries tested, despite supervised rules.
Alex: Huh, so equipment and center limits, plus tiny positive counts, explain some gaps. Looking ahead?
Sam: The paper points to prevalence-agnostic methods—like learning normals deeply to flag outliers—as untried here but promising for abundant good data and rare labels. Future work should test those head-to-head, integrate clinician feedback, and refine for real shifts. Overall, RARE25 lays a foundation: a large public set and prevalence-real tests to build reliable tools aligned with surveillance needs.
Alex: A solid step, then—exposing limits while showing paths forward. Thanks, Sam—that's our look at tackling rare detections in esophageal checks. Thanks for listening to ResearchPod.