Benedikt H. Johanning-Meiners, Luca Mayolle, Dominik Krug, Michael Klaas
7 min
Abstract
The tracheal flow field shapes particle transport into the lower airways and thus influences both the spread of inhaled pathogens and the effectiveness of aerosol-based therapies. Identifying how different inhalation routes modify the flow field is therefore crucial for understanding lower-airway disease transmission and for guiding targeted drug delivery. To gain a detailed understanding of the influence of the inhalation route on the flow structures in the human trachea, the flow field in the trachea is investigated in vitro in a non-compliant, refractive-index matched silicone model of the human respiratory tract. The investigations comprise steady inhalation, and oscillatory flow to simulate calm breathing. A realistic breathing pattern is approximated by a sinusoidal waveform for two Reynolds numbers of $Re_{Tr} = [400, 1200]$, based on the bulk velocity at maximum volume flux and the hydraulic diameter of the trachea and two Womersley numbers of $Wo = [3, 4.5]$, representing the oscillation time scales. To capture the inherently three-dimensional and asymmetric nature of the flow field, 3D particle-tracking velocimetry measurements are performed using the Shake-The-Box algorithm. Using a refractive-index matched fluid consisting of water and glycerin, the complex flow structures inside the trachea are fully resolved. The PTV measurements confirm that the nasal and/or oral cavity must be considered when analyzing the flow field in the lower respiratory tract. In particular, we find that the presence of both cavities significantly alters the flow field compared to idealised, fully developed inflow conditions. However, velocity profiles in the sagittal and coronal plane in the trachea as well as contour plots of the of the normalized velocity magnitude evidence nearly identical flow structures for oral and nasal inhalation, indicating minimal influence of the inhalation route.
Sam: Yes—the flows became nearly identical in the trachea, regardless of entry. Strong jets from the larynx and upper throat overpowered the upstream differences, creating the same skewed patterns and instabilities further down—like a narrow gate that reshapes everything.
Alex: Wait—that means nose or mouth breathing puts germs or medicine in the same spots? Even with the bends and curves up top being so different?
Sam: Precisely. Upstream geometry from nose or mouth has minimal lasting effect, so old models assuming smooth pipe flow badly miss where particles stick, as this study suggests.
Alex: Okay, but to trust those nearly identical flows, they must have checked if their measurements lined up with other methods—how did they do that?
Sam: They compared velocity profiles—snapshots of air speed across slices of the trachea—from their full 3D particle tracking with a simpler 2D technique called Particle Image Velocimetry, or PIV for short. PIV works by shining lights through fluid seeded with tiny particles and photographing their movement in thin sheets to map speeds and directions, like tracking glowing dust in a breeze to see wind patterns. At steady low-speed breathing, the profiles matched closely.
Alex: So the 3D setup holds up. What did those profiles actually look like—smooth and even, or something else?
Sam: Far from smooth. In a straight pipe with no bends upstream, air speed forms a rounded hill shape across the width—faster in the middle, slower at edges—called a parabolic profile. But here, the real airways create an M-shaped profile with two speed peaks, because jets from the larynx squeeze and skew the flow.
Alex: That M-shape from the larynx explains why entry route doesn't matter much downstream. Did slices further down confirm the oral and nasal patterns stay the same?
Sam: Yes—horizontal slices through the trachea showed nearly identical maps of speed for both routes. Each had a bright central streak of fast flow curving into an arc shape toward the back, fading near walls, whether steady or wavy breathing. Oral flow edged slightly faster at peak speeds, but the overall structure matched, underscoring how the throat and voice box erase upstream differences.
Alex: Huh. So no big surprises between nose and mouth—just that consistent skew from the middle section.
Sam: Precisely. This convergence means models skipping realistic larynx effects—like assuming even pipe flow—predict wrong spots for particles from inhalers or viruses.
Alex: Does this hold for breathing out too?
Sam: Yes, exhalation showed even less route influence, as flow starts from the bronchial branches below, bypassing upper paths entirely. Contour maps at peak exhale revealed matching vortex swirls and jets shifted toward one side, varying more with speed than entry type. This reinforces that tracheal geometry—not nose or mouth—drives the patterns.
Alex: Right, so for viruses or inhalers, the windpipe acts like a common funnel.
Sam: Precisely. Upstream routes fade quickly, letting pharynx and larynx dictate where particles go—a meaningful insight for accurate predictions without overcomplicating entries.
Alex: So pulling it all together, the pharynx and larynx are the real bosses here, reshaping air flow into the same patterns no matter the entry point. But for particles like viruses or inhaler drugs, does this mean we can simplify models to just that middle section?
Sam: Yes—the study suggests universal tracheal models focused on pharynx-larynx geometry would capture deposition sites accurately, bypassing nasal-oral variability. Old assumptions of smooth parabolic flow miss these skews, leading to poor device designs. The evidence points to fewer failed predictions in aerosol delivery, though real airways flex and vary between people, so these fixed-shape results are a starting point.
Alex: Fair—speaking of limits, their setup used a stiff silicone cast from one patient's scans, right? No stretching like real tissue.
Sam: Exactly. The rigid model overlooks how soft airways expand and contract, potentially altering flows. Limited to one geometry means broader patient variations aren't covered—the paper implies this as a foundation for future work.
Alex: Well, even with those bounds, it's a solid step toward reliable particle tracking without over-modeling the top end.
Sam: Agreed. By showing route choice has weak influence while upstream realism is key, it guides better computational predictions for therapies and disease spread.
Alex: Thanks, Sam—that clears up why nose and mouth breathing lead to such similar deep-lung effects. Thanks for listening to ResearchPod.